Open Access Open Access  Restricted Access Subscription Access

Entropy Generation Analysis of Fully Developed Laminar Forced Convection in a Confocal Elliptical Duct with Uniform Wall Heat Flux


Affiliations
1 Department of Mechanics, Mahshahr branch, Islamic Azad University, Mahshahr, Iran
 

This paper presents the entropy generation and pumping power for developing forced convection in a confocal elliptical duct with constant heat flux. Entropy generation is obtained for various aspect ratio (ε), various ratio of the minor axis to the major axis (α), various wall heat flux and various Reynolds number. It is found that with the increasing aspect ratio (ε) values and decreasing ratio of the minor axis to the major axis (α), total entropy generation and pumping power at fixed Reynolds number increases; with increasing wall heat flux values, total entropy generation and pumping power decreases; with increasing cross-sectional area of duct values, total entropy generation and pumping power decreases

Keywords

Entropy, Laminar Flow, Confocal Elliptical Duct, Heat Flux
User

  • Bejan A (1994) Entropy generation through heat and fluid flow. Wiley, NY.
  • Bejan A (1996) Entropy generation minimization: the new thermodynamics of finite size devices and finitetime processes. J. Appl. Physics. 79 (3), 1191–218.
  • Dagtekin I, Ozotop HF and Sahin AZ (2005) An analysis of entropy generation through a circular duct with different shaped longitudinal fins for laminar flow. Intl. Communications in Heat & Mass Transfer. 48,171–181.
  • Jarungthammachote S (2010) Entropy generation analysis for fully developed laminar convection in hexagonal duct subjected to constant heat flux. Energy. 35, 5374-5379.
  • Ozotop HF (2005) Effective parameters on second law analysis for semicircular ducts in laminar flow and constant wall heat flux. Intl. Communications in Heat & Mass Transfer. 32, 266–274.
  • Ozotop HF, Dagtekin I and Sahin AZ (2009) Second law analysis of fully developed laminar flow for rectangular ducts with semicircular ends. Intl. Communications in Heat & Mass Transfer. 36,725– 730.
  • Sahin AZ (1998) A second law comparison for optimum shape of subjected to constant wall temperature and laminar flow. Heat & Mass Transfer. 33, 425–430.
  • Sahin AZ (1998) Irreversibilities in various duct geometries with constant wall heat flux and laminar flow. Energy. 23,465–473.
  • Sahin AZ (1998) Second law analysis of laminar viscous flow through a duct subjected to constant wall temperature. J. Heat Transfer. 120, 76–83.
  • Sahin AZ (2000) Entropy generation in turbulent liquid flow through a smooth duct subjected to constant wall temperature. Intl. J. Heat & Mass Transfer. 43, 1469–1478.
  • Shah RK and London AL (1978) Laminar flow forced convection in ducts. Academic Press.

Abstract Views: 364

PDF Views: 114




  • Entropy Generation Analysis of Fully Developed Laminar Forced Convection in a Confocal Elliptical Duct with Uniform Wall Heat Flux

Abstract Views: 364  |  PDF Views: 114

Authors

Alireza Falahat
Department of Mechanics, Mahshahr branch, Islamic Azad University, Mahshahr, Iran

Abstract


This paper presents the entropy generation and pumping power for developing forced convection in a confocal elliptical duct with constant heat flux. Entropy generation is obtained for various aspect ratio (ε), various ratio of the minor axis to the major axis (α), various wall heat flux and various Reynolds number. It is found that with the increasing aspect ratio (ε) values and decreasing ratio of the minor axis to the major axis (α), total entropy generation and pumping power at fixed Reynolds number increases; with increasing wall heat flux values, total entropy generation and pumping power decreases; with increasing cross-sectional area of duct values, total entropy generation and pumping power decreases

Keywords


Entropy, Laminar Flow, Confocal Elliptical Duct, Heat Flux

References





DOI: https://doi.org/10.17485/ijst%2F2011%2Fv4i12%2F30301