Open Access Open Access  Restricted Access Subscription Access

A Calorimetric Study of Ti-6AL-4V Alloy


Affiliations
1 Department of Mechanical Engineering, Annamalai University, India
2 Department of Manufacturing Engineering, Annamalai University, India
3 Thermal Systems Group, ISRO Satellite Centre, Bangalore, India
 

Ti-6Al-4V titanium alloy is widely used in industrial applications such as aeronautic and aerospace due to its good mechanical properties at high temperatures. The aim of the work is to determine the heat capacity of the thermal cycled titanium alloy. The cylindrical specimens of dimension 3 ± 0.1 mm in diameter and 2.5 ± 0.1 mm in length were machined from the CNC machine. The specimens were subject to two different types of heat treatments (Solution treated and annealed). First type of heat treatment (annealing) is processed by heating the specimen to a temperature of 7500°C for 4 hours and it is cooled in the furnace to reach the atmospheric temperature. Second type of heat treatment (solution treating) is processed by the specimen is heated to a temperature of 975°C for 1 hour and it is quenched in a solution containing water with 5% of caustic soda. After quenching (delay of 6 second), aging was done at 450° C for 4 hours and then it is furnace cooled to reach atmospheric temperature The heat treated specimens were thermal cycled in a specially designed thermal cycling apparatus for different cycles heat flow and the flow of energy into or out of the sample as a function of temperature was measured by using Differential Scanning Calorimetry (DSC). The heat flow response is recorded as a function of actual sample temperature range from -120° C to 380° C. The measurements of the heat capacity by DSC with an accuracy of ±2% have been reported. This study restrict the use of DSC as a truly quantitative calorimetric technique and concentrates mainly on the practical set of experimental heat capacity data measured over a temperature range for different aerospace materials being used/developed indigenously for the Indian Space Programme.

Keywords

Thermal Analysis, Differential Scanning Calorimeter, Specific Heat, Heat Treatment
User

  • Gilmore D G (2002). spacecraft thermal control hand book, Aerospace Press, California. Fundamental Technologies, vol 1, 21-71.
  • Lam T T, ed. (1998). Study of advanced satellite thermal management technology, Aerospace Corporation, TOR-98(1057)-2.
  • Geng H and He S (1997). Thermal cycling behavior of As-Quenched and aged Ti-6Al-4V alloy, Metallurgical and Material Transactions A, vol 28(9), 1809-1814.
  • ASM International (1994). Material Properties Handbook: Titanium Alloys.
  • Karthikeyan B, Ramanathan S et al. (2010). A calorimetric study of 7075Al/SiCp composites. International Journal of Materials and Design, vol 31(supplement 1), S92-S95.
  • Ramakrishnan V, Ramasamy A et al. (2002). Characterisation of MMCs by thermophysical measurements 16th National Heat and Mass Transfer Conference & 5th Indian Society for Heat and Mass Transfer/American Society of Mechanical Engineers Heat and Mass Transfer Conference, Calcutta, India, January, 216-222.
  • Karthikeyan B, Ramanathan S et al. (2010). Specific heat capacity measurement of Al/SiCp composites by differential scanning calorimeter, Advanced Materials Research, vols 264-265, 669-674.
  • Basak D, Overfelt R A et al. (2003). Measurement of specific heat capacity and electrical resistivity of industrial alloys using pulse heating techniques, International Journal of Thermophys, vol 24(6), 1721-1733.
  • Kaschnitz E, Reiter P et al. (2002). Thermal expansion of liquid Ti-6Al-4V measured by electrostatic levitation, International Journal of Thermophysics, vol 23, 267.
  • Basak D, Boetinger W J et al. (1999). Effect of heating rate and grain size on the melting behavior of the alloy Nb-47 mass% Ti in pulse-heating experiments, Acta Materialia vol 47(11), 3147-3158.
  • Basak D, Kattner U R et al. (2000). Application of laser polarimetry to the measurement of specific heat capacity and enthalpy of the alloy 53nb-47ti (mass%) in the temperature range 1600 to 2000 k by a millisecond-resolution pulse heating technique, International Journal of Thermophysics vol 21(4), 913-926.
  • Brooks C R (1982). Heat treatment, structure and properties of nonferrous alloys, American Society of Metals, Metals Park, Ohio, 361.
  • Cezairliyan A, Phillips L C et al. (1995). Annual Report: NIST Consortium on casting of aerospace alloys 95.

Abstract Views: 810

PDF Views: 150




  • A Calorimetric Study of Ti-6AL-4V Alloy

Abstract Views: 810  |  PDF Views: 150

Authors

S. Manikandan
Department of Mechanical Engineering, Annamalai University, India
S. Ramanathan
Department of Manufacturing Engineering, Annamalai University, India
V. Ramakrishnan
Thermal Systems Group, ISRO Satellite Centre, Bangalore, India

Abstract


Ti-6Al-4V titanium alloy is widely used in industrial applications such as aeronautic and aerospace due to its good mechanical properties at high temperatures. The aim of the work is to determine the heat capacity of the thermal cycled titanium alloy. The cylindrical specimens of dimension 3 ± 0.1 mm in diameter and 2.5 ± 0.1 mm in length were machined from the CNC machine. The specimens were subject to two different types of heat treatments (Solution treated and annealed). First type of heat treatment (annealing) is processed by heating the specimen to a temperature of 7500°C for 4 hours and it is cooled in the furnace to reach the atmospheric temperature. Second type of heat treatment (solution treating) is processed by the specimen is heated to a temperature of 975°C for 1 hour and it is quenched in a solution containing water with 5% of caustic soda. After quenching (delay of 6 second), aging was done at 450° C for 4 hours and then it is furnace cooled to reach atmospheric temperature The heat treated specimens were thermal cycled in a specially designed thermal cycling apparatus for different cycles heat flow and the flow of energy into or out of the sample as a function of temperature was measured by using Differential Scanning Calorimetry (DSC). The heat flow response is recorded as a function of actual sample temperature range from -120° C to 380° C. The measurements of the heat capacity by DSC with an accuracy of ±2% have been reported. This study restrict the use of DSC as a truly quantitative calorimetric technique and concentrates mainly on the practical set of experimental heat capacity data measured over a temperature range for different aerospace materials being used/developed indigenously for the Indian Space Programme.

Keywords


Thermal Analysis, Differential Scanning Calorimeter, Specific Heat, Heat Treatment

References