A Study on the Bulk Etch Rate of LR-115 Solid State Nuclear Track Detector Using Lithium Hydroxide as an Etching Solution
Among numerous applications of Solid-State Nuclear Track Detector (SSNTD), one important application is estimating radon and thoron concentration in an indoor environment. The primarily used SSNTD for this application is LR-115. Studying the behaviour of these SSNTDs for different etching solutions is essential. In this report, Lithium hydroxide solution was used to etch LR-115 SSNTD. The study of the thickness of the film removed is carried out at different normality of etching solution to study the effect of normality of etching solution on the bulk etch rate. The change in bulk etching rate with the change in temperature of the etching solution was also put out in this study. From the results, it is discovered that the bulk etch rate is directly proportional to the normality and temperature of the etching solution. Additionally, it can be deduced that the LiOH bulk etching rate of LR-115 has lower values when compared to those of other alkaline hydroxide etching solutions.
Keywords
Bulk Etch Rate, Normality, Temperature, LR-115, Lithium Hydroxide.
User
Font Size
Information
- Young D A, Nature, 182 (1958) 375.
- Kaur R, Shikha D, Singh S P & Mehta V, J Geol Soc India, 93 (2019) 603.
- Stojanovska Z, Zunic Z S, Bossew P, Bochicchio F, Carpentieri C, Venoso G & Cosma C, Radiat Prot Dosim, 162 (2014) 152.
- Szeiler G, Somlai J, Ishikawa T, Omori Y, Mishra R, Sapra B K & Kovács T, Radiat Prot Dosim, 152 (2012) 243.
- Kaur R, Singh S P, Shikha D & Mehta V, AIP Conf Proc, 2142 (2019) 120001.
- Benton E V, A study of charged particle tracks in cellulose nitrate, U. S. Naval Défense Laboratory, San Francisco ca, (1968) 1.
- Mehta V, Shikha D, Singh S P, Chauhan R P & Mudahar G S, Nucl Tech Radiat Prot, 31 (2016) 299.
- Monnin M M & Blanford G E, Science, 181 (1973) 743.
- Somogyi G, Nucl Track Detect, 1 (1977) 3.
- Mehta V, Singh S P, Chauhan R P & Mudahar G S, Optoelectron Adv Mater Rapid Commun, 8 (2014) 943.
- Mehta V, Singh S P, Chauhan R P & Mudahar G S, Rom Rep Phys, 67 (2015) 865.
- Palacios D, Sajó-Bohus L, Greaves E D, Palacios F & Barros H, Revista Mexicana de Física, 56 (2010) 22.
- Varshney R, Sonkawade R G, Gupta M, Chauhan R P, Mahur A K, Kant K & Chakarvarti S K, Radiat Meas,46 (2011) 461.
- Yamauchi T, Watanabe S, Oda K, Yasuda N & Barillon R, Radiat Meas, 43 (2008) S116.
- Salama T A, Seddik U, Hegazy T M & Morsy A A, Pramana, 67 (2006) 529.
- Durrani S A & Green P F, Nucl Tracks Radiat Meas, 8 (1984) 21.
- Tse K C C, Ng F M F, Nikezic D & Yu K N, Nucl Instrum Methods Phys Res B: Beam Interact Mater At, 263 (2007) 294.
- Mehta V, Chauhan R P & Mudahar G S, Optoelect Adv Mater Rapid Commun, 7 (2013) 952.