Open Access
Subscription Access
Design and Simulation of Micro-cantilever Based Sensor for Glucose Detection
Subscribe/Renew Journal
Proper management of blood glucose levels is a major challenge in diabetes therapy. To avert further complications in diabetes, glucose level detection is essential. In this work, ZnO-thin film driven micro-cantilever based sensor is designed to determine the blood sugar. The sensor is a Con A/aminopropylsilatrane (APS)-modified piezoelectric cantilever which detects the blood sugar level and estimates the change in mass by monitoring the resonance frequency shift of the cantilever. The finite element modeling of the sensor was carried out using Comsol Multiphysics (ver. 5.2) and results demonstrate that by observing the frequency shift of the cantilever, this sensor can detect glucose level from 50 mg/dL to 500 mg/dL. The mass sensitivity of the proposed sensor is 1.94 x 10-15 g/Hz.
Keywords
Glucose, Zinc Oxide, Cantilever, Frequency, Piezoelectric.
User
Subscription
Login to verify subscription
Font Size
Information
- J. Jia, W. Guan, M. Sim, Y. Li and H. Li, “Carbon Nanotubes Based Glucose Needle-type Biosensor,” Sensors, vol. 8, no. 3, 2008, pp. 1712-1718.
- J. Wang, “Electrochemical Glucose Biosensors,” Chemical Reviews, vol. 108, no. 2, 2008, pp. 814-825.
- D. Tang, Q. Li, J. Tang, B. Su and G. Chen, "An enzyme-free quartz crystal microbalance biosensor for sensitive glucose detection in biological fluids based on glucose/dextran displacement approach", Analytica Chimica Acta, vol. 686, no. 1-2, 2011, pp. 144-149.
- S. Roundy, P. Wright and J. Rabaey, "A study of low level vibrations as a power source for wireless sensor nodes", Computer Communications, vol. 26, no. 11, 2003, pp. 1131-1144.
- Y. Jeon, R. Sood, J. Jeong and S. Kim, “MEMS power generator with transverse mode thin film PZT,” Sensors and Actuators A: Physical, vol. 122, no. 1, 2005, pp. 16-22.
- M. Li, H. Tang and M. Roukes, “Ultra-sensitive NEMS-based cantilevers for sensing, scanned probe and very high-frequency applications,” Nature Nanotechnology, vol. 2, no. 2, 2007, pp. 114-120.
- K. Buchapudi, X. Huang, X. Yang, H. Ji and T. Thundat, “Microcantilever biosensors for chemicals and bioorganisms,” The Analyst, vol. 136, no. 8, p. 1539, 2011.
- U. Sungkanak, A. Sappat, A. Wisitsoraat, C. Promptmas and A. Tuantranont, “Ultrasensitive detection of Vibrio cholerae O1 using microcantilever-based biosensor with dynamic force microscopy,” Biosensors and Bioelectronics, vol. 26, no. 2, 2010, pp. 784-789.
- D. Bhatia, H. Sharma, R. Meena and V. Palkar, “A novel ZnO piezoelectric microcantilever energy scavenger: Fabrication and characterization,” Sensing and Bio-Sensing Research, vol. 9, 2016, pp. 45-52.
- D. DeVoe and A. Pisano, “Surface micromachined piezoelectric accelerometers (PiXLs),” Journal of Microelectromechanical Systems, vol. 10, no. 2, 2001, pp. 180-186.
- D. Isarakorn, D. Briand, P. Janphuang, A. Sambri, S. Gariglio, J. Triscone, F. Guy, J. Reiner, C. Ahn and N. de Rooij, “The realization and performance of vibration energy harvesting MEMS devices based on an epitaxial piezoelectric thin film,” Smart Materials and Structures, vol. 20, no. 2, 2011, p. 025015.
- K. Ekinci, Y. Yang and M. Roukes, "Ultimate limits to inertial mass sensing based upon nanoelectromechanical systems", Journal of Applied Physics, vol. 95, no. 5, 2004, pp. 2682-2689.
- URL: https://www.comsol.co.in/comsol-multiphysics.
Abstract Views: 331
PDF Views: 156