Subscribe/Renew Journal
The paper discussess ome of the practical issues on direct parallel integration of lead acid battery and lead carbon hybrid ultra-capacitor to form an integrated energy storage system for solar power applications. The integrated energy storage system is subjected to various C rates to analyze the behavior of charging and discharging of HUC. The percentage contribution of HUC, in charging and discharging of the integrated energy storage system would be a useful information, while coupling battery and HUC in solar power applications. In view of this, experimental studies have been carried out at different C rates and results are presented.
Keywords
Pb - C HUC/HUC - Lead carbon Hybrid Ultra-capacitor, C rates, an integrated energy storage system