Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Influence of square waveform on life of twisted pairs due to power electronic converters


Affiliations
1 Dept. of EEE Pondicherry Engineering College, Puducherry, India
     

   Subscribe/Renew Journal


Issues in the life of stator winding of electrical motors fed by inverter drives have been concerned about researchers over the last two decades for obtaining adjustable speeds.The Power Electronic Converters produces a square waveform (duty cycle, 50%) with fast rising pulses due to the high switching frequency of IGBT’s, causes premature failure of motor winding insulation. The Life of such motor insulation is tested using twisted pair samples which are prepared using enamel wires.The enamel coating is of Modified Polyester (Class-F insulation) with different makes have the same thickness of 40 microns and Polyester-imide (Class-H insulation) thickness of 40 microns are the two primary insulation tested in this work and the results are compared. The breakdown test was performed with high voltage power frequency sinusoidal waveform and high frequency square waveform of different frequency levels of 5 kHz to 30 kHz. The test results show that breakdown strength of Class F insulation is more than that of Class H insulation.

Keywords

Twisted pairs, switching frequency,primary insulation, breakdown, square wave form
User
Subscription Login to verify subscription
Notifications
Font Size

Abstract Views: 257

PDF Views: 0




  • Influence of square waveform on life of twisted pairs due to power electronic converters

Abstract Views: 257  |  PDF Views: 0

Authors

S. Narasimha Rao
Dept. of EEE Pondicherry Engineering College, Puducherry, India
K. Elanseralathan
Dept. of EEE Pondicherry Engineering College, Puducherry, India

Abstract


Issues in the life of stator winding of electrical motors fed by inverter drives have been concerned about researchers over the last two decades for obtaining adjustable speeds.The Power Electronic Converters produces a square waveform (duty cycle, 50%) with fast rising pulses due to the high switching frequency of IGBT’s, causes premature failure of motor winding insulation. The Life of such motor insulation is tested using twisted pair samples which are prepared using enamel wires.The enamel coating is of Modified Polyester (Class-F insulation) with different makes have the same thickness of 40 microns and Polyester-imide (Class-H insulation) thickness of 40 microns are the two primary insulation tested in this work and the results are compared. The breakdown test was performed with high voltage power frequency sinusoidal waveform and high frequency square waveform of different frequency levels of 5 kHz to 30 kHz. The test results show that breakdown strength of Class F insulation is more than that of Class H insulation.

Keywords


Twisted pairs, switching frequency,primary insulation, breakdown, square wave form



DOI: https://doi.org/10.33686/prj.v13i1.189266