Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Analysis of leakage current during water droplet discharge on silicone rubber adopting rc technique


Affiliations
1 Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai- 600 036, India
2 Easwari Engineering College, Ramapuram, Chennai-600 089, India
     

   Subscribe/Renew Journal


Corona activity can cause reduction in hydrophobicity of silicone rubber insulating material. Leakage current (LC) measured during water droplet discharge was analyzed through Recurrence Plot (RP) analysis. The RP obtained for the leakage current formed due to water droplet discharges under AC and DC voltages are different. Recurrent Quantification Analysis (RQA) is used to quantify the results of RP plots to classify the discharges formed under AC and DC voltages. Multi Resolution Signal Decomposition (MRSD) technique is adopted to understand the frequency contents present in the leakage current at different instants.

Keywords

Corona, leakage current, recurrenceplot, recurrence quantification, Multiresolution signal decomposition
User
Subscription Login to verify subscription
Notifications
Font Size

Abstract Views: 262

PDF Views: 0




  • Analysis of leakage current during water droplet discharge on silicone rubber adopting rc technique

Abstract Views: 262  |  PDF Views: 0

Authors

Palash Mishra
Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai- 600 036, India
G. Parvathy
Easwari Engineering College, Ramapuram, Chennai-600 089, India
R. Sarathi
Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai- 600 036, India

Abstract


Corona activity can cause reduction in hydrophobicity of silicone rubber insulating material. Leakage current (LC) measured during water droplet discharge was analyzed through Recurrence Plot (RP) analysis. The RP obtained for the leakage current formed due to water droplet discharges under AC and DC voltages are different. Recurrent Quantification Analysis (RQA) is used to quantify the results of RP plots to classify the discharges formed under AC and DC voltages. Multi Resolution Signal Decomposition (MRSD) technique is adopted to understand the frequency contents present in the leakage current at different instants.

Keywords


Corona, leakage current, recurrenceplot, recurrence quantification, Multiresolution signal decomposition



DOI: https://doi.org/10.33686/prj.v13i1.189268