Electrical and telecommunication facilities are observed from the past earthquake data, as seismically weak and prone to service failure due to suddenly applied seismic loads. Among them substation equipment are the most vulnerable ones. A need for reliability of electrical equipment against vibrational hazards due to earthquakes has become prime importance. In order to meet the basic requirements regarding seismic qualification of equipment and thereby to ensure reliable power transmission, Earthquake engineering laboratory capable of performing a diverse range of seismic qualification requirements on equipment, sub-assemblies and components as per National and International standards has been established at CPRI, Bangalore. Seismic qualification of few equipment carried out are presented.

Keywords

Seismic qualification, natural frequency, 36 kV circuit breaker, substation equipments
User
Subscription Login to verify subscription
Notifications
Font Size

Abstract Views: 180

PDF Views: 0




  • Seismic response evaluation of substation equipment

Abstract Views: 180  |  PDF Views: 0

Authors

R. Panneer Selvam
Engineering Officer, Central Power Research Institute, Bangalore - 560 080, India
A. N. N. Nampoothiri
Engineering Officer, Central Power Research Institute, Bangalore - 560 080, India
R. Ramesh Babu
Additional Director, Central Power Research Institute, Bangalore - 560 080, India

Abstract


Electrical and telecommunication facilities are observed from the past earthquake data, as seismically weak and prone to service failure due to suddenly applied seismic loads. Among them substation equipment are the most vulnerable ones. A need for reliability of electrical equipment against vibrational hazards due to earthquakes has become prime importance. In order to meet the basic requirements regarding seismic qualification of equipment and thereby to ensure reliable power transmission, Earthquake engineering laboratory capable of performing a diverse range of seismic qualification requirements on equipment, sub-assemblies and components as per National and International standards has been established at CPRI, Bangalore. Seismic qualification of few equipment carried out are presented.

Keywords


Seismic qualification, natural frequency, 36 kV circuit breaker, substation equipments



DOI: https://doi.org/10.33686/prj.v10i3.189483