Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Implementation of Shunt Active Power Filter Based on a Simple Novel Control Algorithm


Affiliations
1 EED, N.G. Patel Polytechnic, Isroli, Afwa Post, Bardoli, Surat, Gujarat, India
2 EED, Sardar Vallabhbhai National Institute of Technology, Surat-395007, Gujarat
     

   Subscribe/Renew Journal


Shunt active power fi lter are commonly used as a harmonic and reactive power compensator. In this paper, a simple control method is described to control shunt active power fi lter. It operates on constant switching frequency, hence switching losses and stresses on the devices are lower. It can compensate the reactive power required by the load without sensing and computing the associated reactive power component, thus control circuit is made simple. It can also compensate harmonic components of the non-linear loads. The experimental results are agreed with the analytical and simulated results.

Keywords

Shunt active power fi lter, Harmonic and reactive power compensator, Simple control method, Donstant switching frequency, Power quality and Active power filter.
User
Subscription Login to verify subscription
Notifications
Font Size

Abstract Views: 247

PDF Views: 0




  • Implementation of Shunt Active Power Filter Based on a Simple Novel Control Algorithm

Abstract Views: 247  |  PDF Views: 0

Authors

Vijay K. Patel
EED, N.G. Patel Polytechnic, Isroli, Afwa Post, Bardoli, Surat, Gujarat, India
M. A. Mulla
EED, Sardar Vallabhbhai National Institute of Technology, Surat-395007, Gujarat

Abstract


Shunt active power fi lter are commonly used as a harmonic and reactive power compensator. In this paper, a simple control method is described to control shunt active power fi lter. It operates on constant switching frequency, hence switching losses and stresses on the devices are lower. It can compensate the reactive power required by the load without sensing and computing the associated reactive power component, thus control circuit is made simple. It can also compensate harmonic components of the non-linear loads. The experimental results are agreed with the analytical and simulated results.

Keywords


Shunt active power fi lter, Harmonic and reactive power compensator, Simple control method, Donstant switching frequency, Power quality and Active power filter.



DOI: https://doi.org/10.33686/prj.v8i4.189786