Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Analytical and Bio Analytical Method for Quantification of Pure Azilsartan, Not its Salts by RP-HPLC


Affiliations
1 Department of Pharmaceutics, Bharati Vidyapeeth College of Pharmacy, Near Chitranagari, Kolhapur-416013, M. S., India
2 Department of Pharmaceutical Chemistry, Bharati Vidyapeeth College of Pharmacy, Near Chitranagari, Kolhapur-416013, M. S., India
     

   Subscribe/Renew Journal


A simple, specific and accurate reverse phase liquid chromatographic method was developed for determination of Azilsartan in its tablet dosage form as well as from biological fluid like plasma. The determination was carried out on ODS Hypersil C18 column (4.6 mm x 250 mm 5μm) column using a mobile phase of acetonitrile: water (pH 4) [60: 40 %v/v]. The flow rate was 1 mL/min with detection at 249 nm. The linearity response of the HPLC system for Azilsartan was obtained over the range 1-64 μg/mL. Ambroxol (25μg/mL) was used as internal standard. Retention time for Azilsartan and ambroxol were found to be 3.74 and 1.84 minutes respectively. The correlation co-efficient (R2 value) for Azilsartan was found to be 0.992. The proposed method was successfully used for quantification of Azilsartan in Azilva tablets and plasma. The method was validated as per ICH Q2B (Analytical) and USFDA (Bio-analytical) guidelines. The results of analysis have been validated statistically and by recovery studies. The method is found useful for quantification of Azilsartan in marketed formulations as well as from biological fluids and can be applied for quantification of Azilsartan in preclinical and clinical studies.

Keywords

Azilsartan, Ambroxol, RP-HPLC, Plasma, ICH Q2B, Bioanalytical Method.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 239

PDF Views: 3




  • Analytical and Bio Analytical Method for Quantification of Pure Azilsartan, Not its Salts by RP-HPLC

Abstract Views: 239  |  PDF Views: 3

Authors

Mukta D. Naykode
Department of Pharmaceutics, Bharati Vidyapeeth College of Pharmacy, Near Chitranagari, Kolhapur-416013, M. S., India
Durgacharan A. Bhagwat
Department of Pharmaceutics, Bharati Vidyapeeth College of Pharmacy, Near Chitranagari, Kolhapur-416013, M. S., India
Swapnil D. Jadhav
Department of Pharmaceutical Chemistry, Bharati Vidyapeeth College of Pharmacy, Near Chitranagari, Kolhapur-416013, M. S., India
Harinath N. More
Department of Pharmaceutical Chemistry, Bharati Vidyapeeth College of Pharmacy, Near Chitranagari, Kolhapur-416013, M. S., India

Abstract


A simple, specific and accurate reverse phase liquid chromatographic method was developed for determination of Azilsartan in its tablet dosage form as well as from biological fluid like plasma. The determination was carried out on ODS Hypersil C18 column (4.6 mm x 250 mm 5μm) column using a mobile phase of acetonitrile: water (pH 4) [60: 40 %v/v]. The flow rate was 1 mL/min with detection at 249 nm. The linearity response of the HPLC system for Azilsartan was obtained over the range 1-64 μg/mL. Ambroxol (25μg/mL) was used as internal standard. Retention time for Azilsartan and ambroxol were found to be 3.74 and 1.84 minutes respectively. The correlation co-efficient (R2 value) for Azilsartan was found to be 0.992. The proposed method was successfully used for quantification of Azilsartan in Azilva tablets and plasma. The method was validated as per ICH Q2B (Analytical) and USFDA (Bio-analytical) guidelines. The results of analysis have been validated statistically and by recovery studies. The method is found useful for quantification of Azilsartan in marketed formulations as well as from biological fluids and can be applied for quantification of Azilsartan in preclinical and clinical studies.

Keywords


Azilsartan, Ambroxol, RP-HPLC, Plasma, ICH Q2B, Bioanalytical Method.