Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

A Sensitive Liquid Chromatography-tandem Mass Spectrometry Method for the Estimation of Cilostazol in Bulk and in a Pharmaceutical Formulation


Affiliations
1 Department of Pharmaceutical Analysis, JSS College of Pharmacy (JSS Academy of Higher Education and Research, Mysuru) Udhagamandalam, India
     

   Subscribe/Renew Journal


The present study reports on a liquid chromatography-tandem mass spectroscopy method for the analysis of Cilostazol drug substance in its formulation. The materials utilize a Zorbax SB C18 analytical column with electrospray ionization and a triple quadrupole mass detector in multiple reaction monitoring (MRM) mode, resulting in a short analysis of 1.5 min runtime and the analyte elute at 0.76 min. Change from SIM to MRM mode resulted in increased sensitivity and low quantitation limit which in turn produces a detection limit of 1 ng/ml. The obtained method was validated in a range of 5-100 ng/ml with a correlation coefficient of 0.9991. The percentage recovery of the present method was found to be in the range of 94% to 100%. The developed method was validated as per the ICH guidelines.

Keywords

Cilostazol, LC-MS/MS Method, Electrospray Ionization, MRM.
Subscription Login to verify subscription
User
Notifications
Font Size


  • Medicine library. Available from: URL: https://medlineplus.gov/druginfo/meds/a601038.html.
  • Alhamide Hoballah SA. Spectrophotometric methods for determination of cilostazol in pure and dosage forms. Int J Res Pharm Chem. 2015; 5(1): 17-26.
  • Lesrari AD, Palupi T, Oktarina B, Yuwono M, Indrayanto G. HPLC determination of Cilostazol in tablets, and its validation. J Liquid Chromatogr Related Tech. 2014; 27(16): 2603-2612
  • Damor D, Mittal K, Patel B, Mashru R. Method development and validation of simultaneous estimation of cilostazol and telmisartan. Res Rev: J Pharm Ana. 2015; 4(3): 41-48.
  • Mohammed E. Abdel-Hamid, Leyla H. Sharaf, Oludotun A. Phillips, Elijah O. Kehinde. A Validated LC-MS/MS Method for the Determination of Tamsulosin Hydrochloride in Six Brands; Applications to Content Uniformity and Dissolution Studies. Research J. Pharm. and Tech. 2011; 4(12): 1885-1890.
  • Mohammed Abdel-Hamid, Leyla H. Sharaf. Use of Stable Labeled Internal Standards LC-MS/MS Method for the Detection and Confirmation of Inherited Metabolic Diseases in Sick Infants. Research J. Pharm. and Tech. 2012; 5(6): 768-774.
  • Surendran Vijayaraj, Anoop Singh, Kokilam Perumal Sampathkumar. Pharmacokinetic Study of Oxime Prodrug of Gliclazide by LC-MS/MS Method in Rabbit Plasma. Asian J. Research Chem. 2015; 8(5): 351-357.
  • ICH, Q3B validation of analytical procedures: methodology, International Conference on Harmonization, November 1996. Available from: URL: https://www.fda.gov/downloads/drugs/guidances/ucm073384.pdf.

Abstract Views: 230

PDF Views: 0




  • A Sensitive Liquid Chromatography-tandem Mass Spectrometry Method for the Estimation of Cilostazol in Bulk and in a Pharmaceutical Formulation

Abstract Views: 230  |  PDF Views: 0

Authors

K. Vishnu
Department of Pharmaceutical Analysis, JSS College of Pharmacy (JSS Academy of Higher Education and Research, Mysuru) Udhagamandalam, India
S. T. Narenderan
Department of Pharmaceutical Analysis, JSS College of Pharmacy (JSS Academy of Higher Education and Research, Mysuru) Udhagamandalam, India
S. Vishnupriya
Department of Pharmaceutical Analysis, JSS College of Pharmacy (JSS Academy of Higher Education and Research, Mysuru) Udhagamandalam, India
B. Babu
Department of Pharmaceutical Analysis, JSS College of Pharmacy (JSS Academy of Higher Education and Research, Mysuru) Udhagamandalam, India
S. N. Meyyanathan
Department of Pharmaceutical Analysis, JSS College of Pharmacy (JSS Academy of Higher Education and Research, Mysuru) Udhagamandalam, India

Abstract


The present study reports on a liquid chromatography-tandem mass spectroscopy method for the analysis of Cilostazol drug substance in its formulation. The materials utilize a Zorbax SB C18 analytical column with electrospray ionization and a triple quadrupole mass detector in multiple reaction monitoring (MRM) mode, resulting in a short analysis of 1.5 min runtime and the analyte elute at 0.76 min. Change from SIM to MRM mode resulted in increased sensitivity and low quantitation limit which in turn produces a detection limit of 1 ng/ml. The obtained method was validated in a range of 5-100 ng/ml with a correlation coefficient of 0.9991. The percentage recovery of the present method was found to be in the range of 94% to 100%. The developed method was validated as per the ICH guidelines.

Keywords


Cilostazol, LC-MS/MS Method, Electrospray Ionization, MRM.

References