Open Access
Subscription Access
Open Access
Subscription Access
Analytical Method Development and Validation for Simultaneous Determination of Ambroxol and Olopatadine Hydrochloride in Synthetic Mixture
Subscribe/Renew Journal
An Absoption Correction UV spectrophotometric and a reversed Phase high-performance liquid chromatographic method for the determination of Ambroxol and Olopatadine Hydrochloride in Synthetic mixture were developed. The Absorption Correction UV spectrophotometric method was found to be accurate with 99.75±0.04 recovery for ambroxol and recovery for olopatadine 99.89±0.02 respectively and method is also precise with a coefficient of variation for olopatadine and ambroxol was 0.996 and 0.885 respectively. For reverse phase HPLC, A reversed-phase C18 column with methanol: ammonium acetate buffer (80:20, v/v, pH 5.5) mobile phase was used and the detector wavelength was set at 244 nm. Linearity range for ambroxol and Olopatadine Hcl was found to be 78-150 μg/ml and 13-25 µg/ml respectively.
Keywords
Ambroxol, Olopatadine Hydrochloride, Absoption Correction UV Spectrophotometry, Reversed Phase HPLC
Subscription
Login to verify subscription
User
Font Size
Information
- Indian Pharmacopoeia. Volume 2. The Indian Pharmacopoeia Commission, Ghaziabad, Govt. of India Ministry of Health and Family Welfare; 2010. Pp.792-793.
- British Pharmacopoeia. Department of Health; Published by the stationery Office on behalf of the medicines and Healthcare products Regulatory Agency (MHRA); Volume I , London, HMSO Publication ;2009. P.118-119.
- European pharmacopoeia 7.0, European Directorate for the quality of medicine and healthcare, p. 1365-1366.
- The United States Pharmacopoeia, 2010 USP 33-NF 28, Rockville MD USA, United States Pharmacopeia Convention Inc, 2007, p. 391-392.
- Budavari S. The Merck Index;13 th ed., Merck and Co. Inc., New Jersey, monograph no.1745, p. 382.
- http://www.chemicalbook.com/ProductMSDSDetailCB0689142 _EN.htm
- http://www.drugbank.ca/drugs/DB00768
- http://pubchem.ncbi.nlm.nih.gov/summary/summary.cgi?cid=52 81071
- http://pubchem.ncbi.nlm.nih.gov/summary/summary.cgi?cid=21 32
- Avhad M, Bonde CG. Development and validation of simultaneous UV Spectroscopic method for the determination of Levofloxacin and Ambroxol in tablets. International Journal of ChemTech Research. 2009; 1(4):873-888.
- Goswami J, Kakadiya J, Shah N. RP-HPLC Method Development and Validation for Simultaneous Estimation of Ambroxol Hydrochloride and Cefpodoxime Proxetile in Pharmaceutical Dosage form. American Journal PharmTech Research 2012;2(3):1043-1052.
- Senthil R, Shan SH, Perumala P and Moorthy MTS. RP-HPLC method development and validation for the simultaneous estimation of azithromycin and ambroxol hydrochloride in tablets. International Journal of PharmTech Research. 2010;2(1):36-39.
- Drops M, Mathrusri A , Bindu GH, Divya I. New Analytical Methods for the Determination of Olopatadine(An Anti-allergic Drug) in Eye. Drug Invention Today. 2012;4(8):441-443.
- Dey S, Reddy YV, Swetha B, Sandeep KD, Murthy PN, Sudhir k, Dhiraj k , Patro S and Mohapatra S. Method Development and validation for the estimation of Olopatadine in bulk and pharmaceutical dosage form and its stress degradation studies using UV -Vis spectrophotometric method. International Journal of Pharmacy and Pharmaceutical Sciences. 2010;2 (4):212-218.
- Varghese SJ, Susheel JK, Manikanta A. Stability-Indicating High-Performance Column Liquid Chromatography and High- Performance Thin-Layer Chromatography Methods for the Determination of Olopatadine Hydrochloride in Tablet Dosage
Abstract Views: 987
PDF Views: 3