In the context of achieving a national set target of 60 GW by 2022, a study was carried out in Kayathar, Tuticorin district, Tamil Nadu, India on noise propagation from wind turbines. Acoustic and non-acoustic parameters were measured according to IEC 61400-11 at wind speeds of 4-13 and 0.7-8.6 m/s. The onsite measurements were compared with ISO 9613-2; this showed a difference of ± 5 dB(A) for every increment in the distance. An equation was derived to obtain sound pressure level (dB(A)) at the base of the tower for wind turbines at varying distance of measurement.
Keywords
Acoustic and Non-Acoustic Parameters, Noise Propagation, Sound Pressure Level, Wind Turbine.