Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Superiority of Narrow Gap SMA Welding of 304 in Stainless Steel Pipe


Affiliations
1 Department of Metallurgical & Materials Engineering., Indian Institute of Technology, Roorkee, India
2 Reactor Safety Division, Bhabha Atomic Research Centre, India
     

   Subscribe/Renew Journal


Shielded metal arc (SMA) welding of 25mm thick wall 325mm O.D, 304LN austenitic stainless steel pipe has been carried out with GTAW ischolar_main pass by using conventional V-groove and narrow groove welding techniques at appropriately designed WPS to produce sound weld of significantly narrow weld groove. The characteristics of the narrow groove weld joints with respect to their weld size, microstructure, residual stresses, mechanical properties and corrosion susceptibility have been studied and compared to those of the conventional V-groove weld joints. It is observed that the use of narrow groove instead of conventional V-groove in welding of thick wall stainless steel pipe is beneficial especially with respect to reduction in grain coarsening at HAZ adjacent to the fusion line and lowering of residual stresses of weld joint by keeping the mechanical properties and susceptibility to IGC comparable to those of the V-groove weld joint. However the inclusion content of the narrow groove SMA weld has been found comparatively higher than that of the conventional V-groove weld.


Keywords

Austenitic Stainless Steel, Shielded Metal Arc Welding, Narrow Gap Welding, V-Groove Welding, Residual Stresses, Microstructure, Inclusion Content, Mechanical Properties, Corrosion.
User
Subscription Login to verify subscription
Notifications
Font Size

Abstract Views: 281

PDF Views: 6




  • Superiority of Narrow Gap SMA Welding of 304 in Stainless Steel Pipe

Abstract Views: 281  |  PDF Views: 6

Authors

Prakriti Kumar Ghosh
Department of Metallurgical & Materials Engineering., Indian Institute of Technology, Roorkee, India
Shrirang Kulkarni
Department of Metallurgical & Materials Engineering., Indian Institute of Technology, Roorkee, India
P. K. Singh
Reactor Safety Division, Bhabha Atomic Research Centre, India
K. K. Vaze
Reactor Safety Division, Bhabha Atomic Research Centre, India

Abstract


Shielded metal arc (SMA) welding of 25mm thick wall 325mm O.D, 304LN austenitic stainless steel pipe has been carried out with GTAW ischolar_main pass by using conventional V-groove and narrow groove welding techniques at appropriately designed WPS to produce sound weld of significantly narrow weld groove. The characteristics of the narrow groove weld joints with respect to their weld size, microstructure, residual stresses, mechanical properties and corrosion susceptibility have been studied and compared to those of the conventional V-groove weld joints. It is observed that the use of narrow groove instead of conventional V-groove in welding of thick wall stainless steel pipe is beneficial especially with respect to reduction in grain coarsening at HAZ adjacent to the fusion line and lowering of residual stresses of weld joint by keeping the mechanical properties and susceptibility to IGC comparable to those of the V-groove weld joint. However the inclusion content of the narrow groove SMA weld has been found comparatively higher than that of the conventional V-groove weld.


Keywords


Austenitic Stainless Steel, Shielded Metal Arc Welding, Narrow Gap Welding, V-Groove Welding, Residual Stresses, Microstructure, Inclusion Content, Mechanical Properties, Corrosion.