Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Performance Evaluation of a Plate Type (HTST) Milk


Affiliations
1 Department of Dairy Engineering, SMC College of Dairy Science, ANAND (GUJARAT), India
     

   Subscribe/Renew Journal


The performance of plate type (HTST) milk pasteurizer was analyzed in a commercial dairy plant having installed capacity of 1.0 lakh lit./day. The purpose of the analysis was to determine the regeneration efficiency and utility usage includes steam, chilled water and electrical energy, in the milk pasteurization processing line. In this dairy plant, the experiment was carried out and results in 89.34 per cent regeneration efficiency achieved. Theoretical and actual steam consumption was determined at rate of 155.72 kg/hr and 156.48 kg/hr, respectively. Chilled water utilization was found to be 25.11 m3/hr i.e. 2.36 times than milk flow rate. Power consumption for milk pasteurization was found to be 16.09 kWh per hour.

Keywords

Milk Pasteurizer, HTST, Steam, Chilled Water, Electrical Energy.
Subscription Login to verify subscription
User
Notifications
Font Size


  • Ahmad, Tufail (1985). Dairy plant engineering and management. Kitab Mahal Chapter 8,pp. 198-207.
  • Gosta, Bylund (1995). Dairy processing handbook. Tetra Pak Processing Systems AB. Chapter -6.1, pp:84-86.
  • Sahay, K.M. and Singh, K.K. (2001). Unit operations of Agricultural process engineering.Vikas Publishing House Pvt. Ltd., Chapter -7 pp: 316-318.

Abstract Views: 340

PDF Views: 0




  • Performance Evaluation of a Plate Type (HTST) Milk

Abstract Views: 340  |  PDF Views: 0

Authors

D. A. Chaudhary
Department of Dairy Engineering, SMC College of Dairy Science, ANAND (GUJARAT), India
A. G. Chaudhari
Department of Dairy Engineering, SMC College of Dairy Science, ANAND (GUJARAT), India

Abstract


The performance of plate type (HTST) milk pasteurizer was analyzed in a commercial dairy plant having installed capacity of 1.0 lakh lit./day. The purpose of the analysis was to determine the regeneration efficiency and utility usage includes steam, chilled water and electrical energy, in the milk pasteurization processing line. In this dairy plant, the experiment was carried out and results in 89.34 per cent regeneration efficiency achieved. Theoretical and actual steam consumption was determined at rate of 155.72 kg/hr and 156.48 kg/hr, respectively. Chilled water utilization was found to be 25.11 m3/hr i.e. 2.36 times than milk flow rate. Power consumption for milk pasteurization was found to be 16.09 kWh per hour.